Leaf Light Simulator

Welcome to The Unlikely Gardener’s Leaf Light Simulator! This interactive 3D tool shows how much light each leaf on a plant actually receives, and why two leaves under the same light can get very different amounts. It models an Alocasia with seven leaves at different angles. Every leaf’s PPFD (Photosynthetic Photon Flux Density) changes with the angle of the leaf to the light, the light’s position and distance, the beam angle, and shading from other leaves. It doesn’t map coverage across a whole grow area like the Grow Light Visualizer or the PAR Map Generator. Used together, they give you a fuller picture of how light reaches your plants, from the room all the way down to a single leaf.

Simply choose window sun or a grow light (bulb, tube or panel), enter your PAR meter reading at the closest leaf, and set the light’s angle, distance and beam spread from your product documentation. Then move the light around the plant or rotate the pot to see the light map change on every leaf. You can view the plant from the front, back, sides, top, or straight down the light beam. The tool calculates PPFD and DLI (Daily Light Integral) for each leaf in real time, so you can find a setup that feeds the whole plant instead of just the leaves facing the light.

The Unlikely Gardener · Interactive

Leaf angle and light: why the same lamp feeds some leaves more than others

Move the grow light or rotate the pot. Each leaf catches light in proportion to how squarely it faces the source, and less when another leaf sits in the way. Light map paints that onto every leaf.

Drag to look around · tap a leaf
PPFD on the leaf’s top surface (µmol/m²/s) · fixed scale
Loading the 3D plant…
Grow light
Where the light is
Seen from above. Drag the light around the ring; tap a leaf to pick it. The eye is your viewpoint.
How high the sun sits. 0° is level with the plant, 90° is straight overhead.

Light reflected off walls, ceiling and furniture, arriving from every direction. It’s why shaded leaves still get some. Set as a % of the meter reading: near 0–5% in a dim room, higher in a bright white one.

Calculating…

1

Leaf 1

Angle to the light
–
Cosine factor
–
Shaded by other leaves
–
Average PPFD
–
Daily light (DLI)
–

Every leaf, average PPFD

Whole plant (area-weighted)–

How this model works: light per unit of leaf area equals the beam’s strength times the cosine of the angle between the beam and the leaf’s surface (Lambert’s cosine law). The meter reading is what a sensor held at the closest leaf, facing the light, would show. Light also loses strength with distance, so leaves farther from the fixture than the closest one get less. Bulbs are treated as one point of light; tubes and panels as evenly spaced LEDs. Other leaves cast shadows, and bounce light adds an even fill. Light reaching only the underside counts as zero. Numbers are estimates for learning, not meter readings.

An interactive from The Unlikely Gardener: evidence-based indoor plant care.
Important Notice
About these numbers: PPFD and DLI values are estimates for learning, not measurements. They are calculated from the meter reading you enter, so their accuracy depends on that reading being taken at the closest leaf with the sensor facing the light. The plant is a single representative Alocasia, not your plant. Bulbs are treated as one point of light. Tubes and panels are treated as evenly spaced LEDs with a smooth beam spread based on the beam angle you enter. Real fixtures vary with LED layout, lens and reflector design, and how the beam angle was measured. Shadows are calculated from other leaves only. Bounce light is treated as an even fill. Light passing through leaves, reflections from nearby surfaces, and light on leaf undersides are not counted. For decisions about your own setup, measure several leaves with a reliable light meter and use this tool to understand why the readings differ.